P&K 3781 (VDI 3781 2)
Beispiel: Geländeprofil III; Standort B
Product has been archived / Produkt wurde archiviert
Correction of the stack height according to VDI 3781 part 2
Geländeprofil III; Standort B
Stack height according to TA Luft [m] | 16,577 |
Waste gas plume rise [m] | 5,9311 |
Corrected stack height [m] | 24,3942 |
List of the schemata |
---|
Parameter | Hill | Valley | Undulation |
---|
x | -1375 | -325 | -859,38 |
a | 154,375 | 195 | 78,2120 |
d | 775 | 650 | 2250 |
beta | 157,469 | 213,398 | 0,03476 |
lambda | 0,12659 | 0,10022 | 0,24987 |
x/d | -1,7742 | -0,5 | -0,1181 |
HE/a | 0,10738 | 0,08501 | 0,21195 |
hE/a | 0,14580 | 0,11543 | 0,28778 |
K | 0,94393 | 0,68835 | 0,82132 |
k | 0,94400 | 0,69194 | 0,82298 |
HG* | 17,5618 | 24,0822 | 20,1833 |
hG* | 23,8434 | 32,5289 | 27,3494 |
delta_H | 6,28167 | 8,13470 | 7,00069 |
HG | 17,5618 | 24,3942 | 20,3487 |